{"product_id":"abb-ms116-0-63","title":"ABB-MS116-0.63","description":"\u003cdiv class=\"row g-0 py-1 py-lg-2 border-bottom\"\u003e\n\u003cdiv class=\"col-md-8\"\u003e\n\u003cdiv class=\"d-print-none ext-attr-val\"\u003e\n\u003cdiv class=\"row g-0 py-1 py-lg-2 border-bottom\"\u003e\n\u003cdiv class=\"col-md-8\"\u003e\n\u003cdiv class=\"d-print-none ext-attr-val\"\u003e\n\u003cdiv class=\"row g-0 py-1 py-lg-2 border-bottom\"\u003e\n\u003cdiv class=\"col-md-8\"\u003e\n\u003cdiv class=\"d-print-none ext-attr-val\"\u003e\n\u003cdiv class=\"row g-0 py-1 py-lg-2 border-bottom\"\u003e\n\u003cdiv class=\"col-md-8\"\u003e\n\u003cdiv class=\"d-print-none ext-attr-val\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eMS116-0.63 Manual Motor Starter 0.40 ... 0.63 A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row g-0 py-1 py-lg-2 border-bottom\"\u003e\n\u003cdiv class=\"col-md-4\"\u003e\n\u003cdiv class=\"d-flex\"\u003e\n\u003cdiv class=\"w-100\"\u003e\n\u003cdiv class=\"ps-lg-3\"\u003e\u003cspan class=\"d-inline-block w-100 text-wrap fw-bold ext-attr-name\"\u003eLong Description:\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-8\"\u003e\n\u003cdiv class=\"d-print-none ext-attr-val\"\u003e\n\u003cdiv\u003e\n\u003cdiv\u003eThe MS116-0.63 manual motor starter (also known as motor protection circuit breaker or manual motor protector) is a compact 45 mm width device with a rated operational current of Ie = 0.63 A. This device is used to manually switch on and off motors and to protect them reliably and without the need f\n\u003cdiv class=\"hiddenlongDescription\"\u003eor a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 50 kA at 400 VAC and trip class 10A. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks and locking devices for protection against unauthorized changes are available as accessory.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"ABB","offers":[{"title":"0.40 ... 0.63 A","offer_id":48816590553243,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/5145\/4875\/files\/350C6FFcopy_270966d8-761f-4a3d-8f63-bdac0c0d0bf2.jpg?v=1781946204","url":"https:\/\/www.naim.com.lb\/products\/abb-ms116-0-63","provider":"Naim electric","version":"1.0","type":"link"}